I'm in the area and licensed in the county. PM if interested......not a danger but it is not code compliant.
Broncolou is offline   Reply With Quote
Old July 29th, 2020, 04:08 PM #32
Slackdaddy's Avatar
Slackdaddy Slackdaddy is offline
Member
 
Join Date: Jan 2019
Posts: 258
Slackdaddy Slackdaddy is offline
Member
Slackdaddy's Avatar
 
Join Date: Jan 2019
Posts: 258
They are correct, 2 gounds under a lug - OK, 2 neutrals - Not OK,
That said. I have been in the home rehab, selling, flipping for 25+ years,, inspectors have tanked more closings over non issues than anyone else.

We will do a cosmetic rehab (roof, int/ext painting, cabinets, etc) on a 1960s house,, get a contract, the buyers inspector sends the usual list of "not to code" (GFIs, railings, etc).
Our response is "please send us a copy of the code from 1962 when this house was built"
There are a few really good inspectors, most are the franchise clowns that do not have a clue.

Now that said,,, if the request are minor,, we will take care of them to shove the sale through.

And having said that,,, My youngest (18) is going into the electrical trade.
Slackdaddy is offline   Reply With Quote
Old Yesterday, 09:20 AM #33
madmantrapper's Avatar
madmantrapper madmantrapper is offline
Senior Member
 
Join Date: Feb 2009
Location: Carroll County
Posts: 1,046
madmantrapper madmantrapper is offline
Senior Member
madmantrapper's Avatar
 
Join Date: Feb 2009
Location: Carroll County
Posts: 1,046
Quote:
Originally Posted by Broncolou View Post
I'm in the area and licensed in the county. PM if interested......not a danger but it is not code compliant.
Depending on when it was done.
madmantrapper is offline   Reply With Quote
Old Yesterday, 07:03 PM #34
antco antco is offline
Senior Member
 
Join Date: Apr 2010
Location: Calvert, MD
Posts: 3,308
antco antco is offline
Senior Member
 
Join Date: Apr 2010
Location: Calvert, MD
Posts: 3,308
Quote:
Originally Posted by TyFromMD View Post
Selling my house, inspector says a panel that was inspected and deemed acceptable 6 years ago is not acceptable now. Need a rewire in Parkton, MD. Please help.

Sent from my SM-G965U using Tapatalk
I have the cover off so I just now took a look inside of my 200 amp Challenger panel, approved by the Calvert Country inspector James Dowell on 1-12-1990, and it’s like yours. It even has neutrals and grounds landed together under one screw on the neutral bars. Gasp. Oh, the humanity.
__________________
"A bureaucrat is the most despicable of men, though he is needed as vultures are needed, but one hardly admires vultures whom bureaucrats so strangely resemble. I have yet to meet a bureaucrat who was not petty, dull, almost witless, crafty or stupid, an oppressor or a thief, a holder of a little authority in which he delights, as a boy delights in possessing a vicious dog. Who can trust such creatures."

-Cicero 50 B.C.

antco is offline   Reply With Quote
Old Yesterday, 07:37 PM #35
Rich1911's Avatar
Rich1911 Rich1911 is offline
Senior Member
 
Join Date: Mar 2012
Posts: 1,945
Images: 1
Rich1911 Rich1911 is offline
Senior Member
Rich1911's Avatar
 
Join Date: Mar 2012
Posts: 1,945
Images: 1
Quote:
Originally Posted by antco View Post
I have the cover off so I just now took a look inside of my 200 amp Challenger panel, approved by the Calvert Country inspector James Dowell on 1-12-1990, and itís like yours. It even has neutrals and grounds landed together under one screw on the neutral bars. Gasp. Oh, the humanity.
Someone over the last 30 years could have added breakers to the panel...
Rich1911 is offline   Reply With Quote
Old Yesterday, 11:57 PM #36
Grampa G Grampa G is offline
Senior Member
 
Join Date: Jan 2010
Location: Washington Co.
Posts: 1,493
Grampa G Grampa G is offline
Senior Member
 
Join Date: Jan 2010
Location: Washington Co.
Posts: 1,493
Common practice but became a separate NEC violation in 2002. Well, really it was a violation prior to that but for not following manufacture's instruction on terminating wires.
Grampa G is offline   Reply With Quote
Reply

  Home Page > Forum List > General > Jobs Board


Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 04:23 PM.


Powered by vBulletin® Version 3.8.9
Copyright ©2000 - 2020, vBulletin Solutions, Inc.
© 2019, Congregate Media, LP Privacy Policy Terms of Service